24-Hour MultiWave® Basic Control , 5-Circuit, 80 A Load Center, Type 3R Metal Enclosure
Model#PE30065RC
- Proposition 65 warning for California residents
24-Hour MultiWave® Basic Control , 5-Circuit, 80 A Load Center, Type 3R Metal Enclosure
Model#PE30065RC
- Proposition 65 warning for California residents
- Supportingsoftware downloadsavailable
- Eight breaker spaces
- Controls 5 circuits
- Controls pumps, lights, cleaners and heaters
- Operates single, two and Pentair® IntelliFlo® and IntelliPro® variable-speed pumps
- 24-hour timing with 3 ON/OFF events per circuit
- Includes receiver, wireless remote, water and air temperature sensors, (3) AA batteries, equipment labels, flathead screwdriver, raintight enclosure, raintight cap and mount for remote mounting antenna
- See MultiWave ECS and ECS Plus Systems for additional control options
- Type 3R indoor/outdoor metal load center
- Four knockouts for GFCIs and switches
- Heater Thermostat Control
- Motor Control
- Pump Control
Number Of Circuits 5 Resistive 20 A, 120 VAC, 20 A, 240 VAC Warranty Period 2-Year limited CAProp65Message Please see the Warning @ www.P65Warnings.ca.gov Circuit 1 Motor Display 80 LRA @120/240 VAC; 17 FLA @120/240 VAC Circuit 1 Resistive Display 20 A Circuit 2 to 5 Motor Display 60 LRA @120/240 VAC; 10 FLA @120/240 VAC Circuit 2 to 5 Resistive Display 15 A Country Of Origin China Knockout Dimensions Back (4) combination 1/2" - 3/4", and (2) combination 3/4" - 1" Knockout Dimensions Bottom (1) 1 1/8" diameter hole, (6) combination 1/2" - 3/4", (4) 1/2", (2) combination 1 1/8" - 1 3/8" - 1 11/16" Knockout Dimensions Left (2) combination 1/2" - 3/4" Knockout Dimensions Right (1) 1 3/4" x 2 3/4" for mounting switches or GFCI Load Center Rating Display 80 A, 120/240 VAC or 120/208 VAC, Single Phase Load Center Ratings 80 A, 120 VAC, 80 A, 208 VAC, Single Phase, 80 A, 240 VAC Motor Load Ratings Circuits 2 - 5 10 FLA @ 120 VAC, 50 Hz, 10 FLA @ 120 VAC, 60 Hz, 10 FLA @ 240 VAC, 50 Hz, 10 FLA @ 240 VAC, 60 Hz, 60 LRA @ 120 VAC, 50 Hz, 60 LRA @ 120 VAC, 60 Hz, 60 LRA @ 240 VAC, 50 Hz, 60 LRA @ 240 VAC, 60 Hz Motor Three Phase Ranges 80 LRA @ 120/240 VAC, 50/60 Hz; 17 FLA @ 120/240 VAC, 50/60 Hz Resistive Load Ratings Circuits 2 - 5 15 A, 120 VAC, 15 A, 240 VAC Transformer Input Voltage 120 VAC, 60 Hz Transformer Output Voltage 12, 13, 14 VAC Tungsten (NO) 5 A Auto Start/Stop False Product Depth (in) 4.75 Product Depth (mm) 120.7 Product Height (in) 22.875 Product Height (mm) 581 Product Width (in) 14.875 Product Width (mm) 377.8 Unit Carton Height (in) 13.5 Unit Carton Length (in) 26.75 Unit Carton Weight (lb) 33.55 Unit Carton Width (in) 19